Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Radiol. bras ; 41(5): 325-329, set.-out. 2008. graf, tab
Article in English, Portuguese | LILACS | ID: lil-496937

ABSTRACT

OBJETIVO: Os objetivos deste trabalho são: a) avaliar os procedimentos radiográficos e estimar o valor do kerma no ar na superfície de entrada nos recém-nascidos prematuros submetidos a exames de tórax e abdome, realizados no setor de neonatologia de um hospital público de Belo Horizonte; b) estimar as doses nos órgãos e os respectivos riscos de ocorrência de câncer nesses órgãos em decorrência das exposições à radiação. MATERIAIS E MÉTODOS: Foram analisados os prontuários dos pacientes internados no setor de neonatologia desse hospital durante o período de maio a setembro de 2004, anotando-se os dados antropométricos, data de internação/alta, exames de raios X realizados. O kerma no ar na superfície de entrada foi determinado a partir do rendimento do tubo de raios X e dos parâmetros de irradiação utilizados nos exames. As doses nos órgãos foram estimadas com o software PCXMC e o risco, durante o restante da expectativa de vida, com o software IREP. RESULTADOS: O valor médio do kerma no ar na superfície de entrada por exame foi abaixo do nível de referência da publicação da Comunidade Européia. Para o paciente mais severamente irradiado, os órgãos mais suscetíveis à ocorrência de câncer foram fígado, mama e estômago, com valores máximos de excess relative risk, respectivamente, de 3,4 por cento, 2,3 por cento e 1,7 por cento. CONCLUSÃO: Foi constatada a necessidade de otimização dos procedimentos radiográficos com vista à diminuição do risco para os recém-nascidos, que apesar de ser considerado baixo (comparativamente ao benefício), deve ser sempre diminuído para valores tão baixos quanto razoavelmente exeqüíveis.


OBJECTIVE: The present study was aimed at: a) evaluating radiographic procedures and estimating entrance surface air kerma in preterm neonates submitted to chest and abdominal radiography at the unit of neonatology in a public hospital of Belo Horizonte, MG, Brazil; b) estimating the dose to organs and respective risks for cancer as a result from radiation exposure. MATERIALS AND METHODS: Records of patients admitted to the unit of neonatology of this hospital in the period between May and September 2004 were reviewed. Anthropometric data, admission/discharge dates and radiographic studies performed were recorded for each of the patients. The calculation of the entrance surface air kerma was based on the x-ray tube output and irradiation parameters adopted for examinations. Dose to organs was calculated with the aid of the software PCXMC, and the lifetime risk for cancer, with the software IREP. RESULTS: Mean entrance surface air kerma per examination was below the diagnostic reference levels recommended by the European Community. In the most severely irradiated patients, liver, breast and stomach were the organs at highest risk for cancer, with maximum excess relative risk of respectively 3.4 percent, 2.3 percent, and 1.7 percent. CONCLUSION: The present study demonstrated the need for optimization of radiographic procedures in order to reduce the risks for neonates that, in spite of being considered to be low as compared with the benefits, should be reduced to values as low as reasonably achievable.


Subject(s)
Humans , Male , Female , Infant, Newborn , Dosimetry/adverse effects , Kerma , Neoplasms, Radiation-Induced , Radiation Protection , Radiation Risks , Carcinogens , Radiation, Ionizing , Radiometry , Risk Assessment
2.
Radiol. bras ; 40(6): 409-413, nov.-dez. 2007. graf, tab
Article in English, Portuguese | LILACS | ID: lil-472001

ABSTRACT

OBJETIVO: Avaliar a freqüência das incidências radiográficas realizadas nos seios da face de pacientes pediátricos em hospitais de Belo Horizonte, MG, as condições de radioproteção, as técnicas radiográficas empregadas, o kerma no ar de entrada e as doses nos órgãos mais expostos. MATERIAIS E MÉTODOS: Foram coletados os dados dos pacientes e parâmetros de técnica radiográfica empregados em exames de crianças de 1 a 16 anos de idade, em cinco salas de quatro hospitais da cidade, observando, também, aspectos de proteção radiológica. O kerma no ar de entrada foi estimado a partir dos rendimentos dos tubos de raios-x e as doses nos órgãos utilizando o software PCXMC. RESULTADOS: Os valores médios do kerma no ar de entrada para as cinco salas foram, respectivamente, 1.398 µGy, 829 µGy, 877 µGy, 1.168 µGy e 3.886 µGy para pacientes entre 1 e 5 anos de idade. CONCLUSÃO: Foi constatado que as incidências mento-naso e fronto-naso são comumente solicitadas em conjunto, na maioria dos hospitais, o que confere dose significativa para os pacientes. Os riscos para os pacientes podem ser diminuídos mediante a utilização de cilindros de colimação, a não-utilização de grades antiespalhamento, o emprego de altos valores de tensão e baixos valores de tempo.


OBJECTIVE: The present study was aimed at evaluating the frequency of radiographic assessment of paranasal sinuses in pediatric patients in hospitals of Belo Horizonte, MG, Brazil. Additionally, aspects regarding radiation protection conditions and radiographic parameters were evaluated, and entrance air kerma and organ doses were estimated. MATERIALS AND METHODS: Patients' data and parameters of radiographic technique employed in the assessment of children in the age range between 1 and 16 years were collected in five examination rooms of four hospitals in Belo Horizonte, also taking into consideration the radiation protection aspects. Entrance air kerma calculation was based on the x-ray tubes output, and organ doses were estimated with the PCXMC software. RESULTS: Mean entrance air kerma values found in the five rooms were, respectively, 1398 µGy, 829 µGy, 877 µGy, 1168 µGy and 3886 µGy for patients with ages between 1 and 5 years. CONCLUSION: Most frequently, mento-naso and fronto-naso views are requested in conjunction in the majority of hospitals, which increases the radiation dose to the patients. It may be concluded that the risks for patients can be reduced by means of the utilization of an appropriate x-ray field, non-utilization of antiscattering grids, selection of high voltages and lower exposure times.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Adolescent , Radiation Exposure , Radiation, Ionizing , Dose-Response Relationship, Radiation , Sinusitis , Radiation Dosage , Kerma
3.
Radiol. bras ; 40(5): 331-336, set.-out. 2007. graf, tab
Article in English, Portuguese | LILACS | ID: lil-467769

ABSTRACT

OBJETIVO: A análise crítica da metodologia de medida da camada semi-redutora em feixes de raios X teve como base o regulamento técnico para proteção radiológica e controle de qualidade em radiodiagnóstico médico e odontológico. MATERIAIS E MÉTODOS: Na medida da camada semi-redutora, a técnica radiográfica, o arranjo experimental, os meios espalhadores, a instrumentação, o tamanho de campo de radiação e a metodologia de análise dos dados foram considerados. RESULTADOS: A camada semi-redutora obtida em condições de boa geometria, para a técnica escolhida, foi de 2,44 ± 0,02 mmAl. Em relação a este valor, observaram-se desvios máximos na camada semi-redutora de 4,1 por cento na variação da geometria, de 98,8 por cento na variação da câmara de ionização e do meio espalhador, e de até 29,5 por cento com outro tipo de detector. CONCLUSÃO: Os resultados mostraram que não ocorre variação significante na camada semi-redutora para diferentes tamanhos de campo de radiação, mas foram evidentes a influência do espalhamento na superestimação da camada semi-redutora e a redução desta na presença de blocos de chumbo como meio espalhador. O procedimento prático adotado mostrou-se bastante confiável e evidenciou a grande discrepância decorrente da adoção de metodologias impróprias, enfatizando a necessidade de estabelecer um procedimento padrão para a medida da camada semi-redutora.


OBJECTIVE: The critical analysis of the methodology for evaluating the x-ray beam half-value layer was based on technical standards for radiological protection and quality control in medical and dental diagnoses. MATERIALS AND METHODS: Exposure parameters, experimental set-up, scattering materials, instrumentation, size of radiation field and methodology of data analysis have been taken into consideration for measurements of half-value layer. RESULTS: The half-value layer, in good geometry, measured 2.44 ± 0.02 mmAl. A maximum deviation of 4.1 percent was found under other geometry conditions. A 98.8 percent deviation was observed with a different ionization chamber, and scattering material, and 29.5 percent with another type of detector. CONCLUSION: Results showed that no relevant variation is observed in the half-value layer for different radiation field sizes. On the other hand, the influence of the radiation scattering on the half-value layer overestimation was clearly observed, as well as the half-value layer reduction in the presence of lead used as scattering material. The practical methodology adopted for half-value layer evaluation has shown to be quite reliable, besides evidencing remarkable discrepancies resulting from the adoption of inappropriate methodologies, emphasizing the necessity of establishing a standard procedure for measuring the half-value layer.


Subject(s)
Radiation Protection/methods , Radiology/instrumentation , Radiology/standards , Radiometry/methods , Technology, Radiologic , Radiation Dosage , Quality Control , Radiation Protection
5.
J. bras. med ; 77(1): 34-38, jul. 1999. ilus
Article in Portuguese | LILACS | ID: lil-314112

ABSTRACT

Os autores apresentam um caso de doença de Urbach-Wiethe (hialinose cutaneomucosa, proteinose lipóide) em mulher de 36 anos, com baixa estatura, voz fina e rouca desde a infância, face envelhecida, pele espessada, com lesões papulares e verrucosas, e bordas palpebrais apresentando aspecto clássico de "colar de pérolas". O diagnóstico foi conformado pelo achado radiológico patognomônico de calcificações cerebrais e exame histopatológico. É uma doença rara, com cerca de 200 casos descritos na literatura mundial e 13 no Brasil


Subject(s)
Humans , Lipid Metabolism, Inborn Errors/physiopathology , Lipoid Proteinosis of Urbach and Wiethe
6.
Arq. gastroenterol ; 36(2): 63-7, Apr.-Jun. 1999. tab
Article in Portuguese | LILACS | ID: lil-241211

ABSTRACT

Devido à limitada eficácia do alfa-interferon no tratamento da hepatite crônica C, o cloridrato de amantadina foi proposto como possível alternativa terapêutica. Entretanto, são poucos os estudos sobre a eficácia dessa droga na hepatite crônica C, sendo seus resultados controversos. Com a finalidade de avaliar os efeitos da amantadina sobre os níveis séricos de alanina aminotransferase e carga viral, 18 pacientes (14 homens e 4 mulheres) portadores crônicos de VHC não-respondedores a curso prévio de alfa-interferon foram selecionados para estudo prospectivo aberto, durante o qual receberam 100 mg da droga via oral de 12/12 horas, por quatro meses. Critérios de inclusão: presença de RNA no soro, níveis elevados de alanina aminotransferase, inflamação crônica hepática e consentimento informado escrito. De acordo com os achados de biopsia hepática pré-tratamento, o grupo constituiu-se de 14 portadores de hepatite crônica (hepatite crônica persistente n = 6, hepatite crônica ativa n = 8) e de 4 portadores de cirrose hepática. O genótipo do VHC mais freqüentemente encontrado em 17 pacientes testados foi o 3a (n = 9,52,94 por cento), seguido do 1b (n = 6, 32,29 por cento). A carga viral (amplicor HCV Monitor, Roche, EUA) e o nível de alanina aminotransferase foram avaliados pré e pós-tratamento. Dezessete pacientes completaram com boa tolerância. Em um caso, a droga foi suspensa por depressão severa. Comparando-se os valores médios basais de alanina aminotransferase e carga viral com os obtidos ao término do tratamento, não se observou redução estatisticamente significativa: alanina aminotransferase antes e depois, respectivamente 139,118 + 79,789 vs 99,588 + 62,583 U/l (P = 0,059) e carga viral pré e pós-tratamento, respectivamente 7,154 + 1,596 vs 6,574 + 1,584 log copias/ml (P = 0,147). O presente estudo não mostrou benefício pelo uso isolado da amantadina no tratamento de portadores de hepatite crônica C não-respondedores ao alfa-interferon. Os autores sugerem a necessidade de estudos com amantadina isolada em pacientes virgens de tratamento para a real definição de sua eficácia em relação à obtida pelo uso de interferon.


Subject(s)
Adult , Middle Aged , Female , Humans , Alanine Transaminase/blood , Amantadine/therapeutic use , Antiviral Agents/therapeutic use , Hepatitis C, Chronic/drug therapy , Interferon-alpha/therapeutic use , RNA, Viral/drug effects , Alanine Transaminase/drug effects , Prospective Studies
7.
Rev. méd. Paraná ; 52(3/4): 1-4, jul.-dez. 1995. tab
Article in Portuguese | LILACS | ID: lil-181187

ABSTRACT

No período de 24 de setembro de 1991 a 31 de setembro de 1995 foram realizados 35 transplantes hepáticos no Hospital de Clínicas da Universidade Federal do Paraná. A idade dos pacientes variou de 6 a 57 anos, com média de 26 anos. As indicaçöes do procedimento foram bastante variáveis e as mais comuns foram a cirrose criptogenética, cirrose por hepatite autoimune, cirrose alcoólica por hepatite C. Trinta e quatro implantes foram realizados de 1 a 4 horas após a retirada do fígado do doador e um 12 horas após. O implante foi realizado com todo o fígado em 34 pacientes e com os segmentos I, II, III e IV em um paciente. As complicaçöes pós-operatórias mais frequentes foram a rejeiçäo celular, insuficiência renal aguda, síndrome da angústia respiratória do adulto e trombose da artéria hepática. Seis pacientes (17 por cento) foram a óbito durante a internaçäo hospitalar e sete (20 por cento) faleceram no pós-operatório tardio (seguimento de 1 a 48 meses). As causas de óbito foram múltiplas e a principal foi a infecçäo viral. A qualidade de vida após 6 meses de transplante é muito boa, com o paciente retornando às suas atividades normais


Subject(s)
Child , Adolescent , Adult , Middle Aged , Humans , Male , Female , Liver Diseases , Liver Cirrhosis , Graft Rejection , Liver Transplantation , Liver Diseases/surgery
8.
Rev. méd. Paraná ; 52(3/4): 5-7, jul.-dez. 1995. tab
Article in Portuguese | LILACS | ID: lil-181188

ABSTRACT

Transplante hepático é hoje uma forma aceita e bem sucedida de tratamento de doença hepática avançada. Há contudo desconhecimento de grande parcela da classe médica a respeito das suas indicaçöes e contra-indicaçöes, bem como aos resultados deste procedimento. Tem este trabalho o propósito de delinear as indicaçöes e contra-indicaçöes do transplante hepático


Subject(s)
Liver Diseases , Liver Cirrhosis , Liver Transplantation , Liver Diseases/surgery
9.
Rev. méd. Paraná ; 52(3/4): 8-10, jul.-dez. 1995. tab
Article in Portuguese | LILACS | ID: lil-181189

ABSTRACT

O transplante hepático é considerado a única forma de tratamento da falência hepática crônica e uma das mais eficientes para a insuficiência hepática aguda. Foram revisados os atestados de óbitos na regiäo metropolitana de Curitiba durante os anos de 1990 a 1994, sendo os dados fornecidos pelo Centro de Epidemilogia e Divisäo de Estatísticas da Secretaria de Saúde do Paraná. Foram considerados os dados de sexo, idade e causa de óbito, seguindo a Classificaçäo Internacional de Doenças (CID). O total de óbitos registrados foi de 13408, 13845, 12899, 13550, 13292, para os anos de 90, 91, 92, 93, e 94 respectivamente. As doenças hepáticas foram causa de óbito em 283 pacientes (2,11 por cento do total) no ano de 1990. 264 (2,05 por cento) em 91, 328 (2,54 por cento) em 92, 303 (2,23 por cento) no ano de 93 e 328 (2,46 por cento) em 1994. A cirrose foi causa de óbito em 266 pacientes em 90 (1,98 por cento do total), 239 (1,72 por cento) em 91, 261 (2,02 por cento) em 92, 229 (1,69 por cento) em 93, e 260 (1,95 por cento) em 94, sendo que a maioria dos pacientes se encontram na faixa etária de 30 anos a 65 anos. Podemos observar que vários óbitos por doença hepática poderiam ser tratados com transplante de fígado, para o qual, a existência e implementaçäo de um centro especializado estäo plenamente justificadas, pois estima-se a necessidade de um transplante a cada 25000 habitantes na regiäo metropolitana de Curitiba


Subject(s)
Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Humans , Male , Female , Liver Failure, Acute , Liver Diseases , Liver Cirrhosis , Liver Transplantation
SELECTION OF CITATIONS
SEARCH DETAIL